net: dsa: mt7530: Fix traffic flooding for MMIO devices
[ Upstream commit ccc2f5a436fbb0ae1fb598932a9b8e48423c1959 ]
On MMIO devices (e.g. MT7988 or EN7581) unicast traffic received on lanX
port is flooded on all other user ports if the DSA switch is configured
without VLAN support since PORT_MATRIX in PCR regs contains all user
ports. Similar to MDIO devices (e.g. MT7530 and MT7531) fix the issue
defining default VLAN-ID 0 for MT7530 MMIO devices.
Fixes: 110c18bfed ("net: dsa: mt7530: introduce driver for MT7988 built-in switch")
Signed-off-by: Lorenzo Bianconi <lorenzo@kernel.org>
Reviewed-by: Chester A. Unal <chester.a.unal@arinc9.com>
Link: https://patch.msgid.link/20250304-mt7988-flooding-fix-v1-1-905523ae83e9@kernel.org
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
9cc7f00186
commit
88afbcb450
@@ -2640,7 +2640,8 @@ mt7531_setup_common(struct dsa_switch *ds)
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
return 0;
|
||||
/* Setup VLAN ID 0 for VLAN-unaware bridges */
|
||||
return mt7530_setup_vlan0(priv);
|
||||
}
|
||||
|
||||
static int
|
||||
@@ -2734,11 +2735,6 @@ mt7531_setup(struct dsa_switch *ds)
|
||||
|
||||
mt7531_setup_common(ds);
|
||||
|
||||
/* Setup VLAN ID 0 for VLAN-unaware bridges */
|
||||
ret = mt7530_setup_vlan0(priv);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
ds->assisted_learning_on_cpu_port = true;
|
||||
ds->mtu_enforcement_ingress = true;
|
||||
|
||||
|
||||
Reference in New Issue